Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 16.04:00 — HP DesignJet L26500

Code: 16.04:00

Description: Curing system temperature too low (below 5C). Curing System has exceeded the lower temperature level.
Remedy: • Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer´s operating specifications; it should be higher than 15C for correct printer operation. If this is the case, increase the ambient temperature of the printer´s location. • Check if the Curing IR Temperature sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check if there is an obstacle blocking the view of the Curing IR Sensor. Check that it is correctly installed with no interference in the IR path. • Check the power going to the Curing IR temperature sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30C. • Check the position of the Curing IR temperature sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the IR sensor check diagnostic g8.4 Curing IR sensorh ËPage 170, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required ËPage 510. • Replace the Heaters Control Assembly ËPage 465.

← Xem tất cả mã lỗi HP DesignJet L26500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie