Code: 15.02:00
Description: Drying system cool-down timed out
Causes: The drying system is unable to cool down in the pre-defined amount of time.
Remedy: 1. Check that the room temperature is within the printer¡¦s operating specifications. If necessary, remove external sources of heat, such as strong lights, direct sunlight, or heaters. 2. This system error can occur if the ¡¥Minimum Drying Power¡¦ setting in the RIP is too high. Set the Minimum Drying Power to 0, and check whether the error repeats. 3. Check there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. 4. Check that all the fans are functioning correctly. Check that the cables of the fans are undamaged and connected. Replace any fans if required: Top Cover Fans. Drying Fans. Curing Fans.