Code: 16.01:00
Description: Curing system warn-up timed out
Causes: Problem description: The curing system is unable to warm up in the pre-defined amount of time (to 45°C for standby and 95°C to 115°C for printing).
Remedy: 1. Check that the room temperature is within the printer's operating specifications; it should be higher than 15°C for printer operation. If it is too low, increase the room temperature. 2. Check that the input voltage is within the printer¡¦s operating specifications: see the Site Preparation Guide. 3. Check whether the substrate loaded on the printer is too transparent or reflective for the IR sensor to detect the surface temperature. You can check this by loading another type of substrate. 4. Check whether the Curing IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 5. Check for an obstacle blocking the IR sensor¡¦s view. Ensure that the IR sensor is correctly installed on the printer, with no interference in the infrared light path, and that it is pointing to the substrate. 6. Perform the Curing IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required. 7. Replace the cables from the PrintMech PCA to the connection box. 8. Replace the PrintMech PCA.