Code: 16.03:00
Description: Curing system temperature too high
Causes: The curing system has exceeded the upper temperature limit (150°C).
Remedy: 1. Check that the room temperature is within the printer¡¦s operating specifications. If necessary, remove external sources of heat, such as strong lights, direct sunlight, or heaters. 2. Check that the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct orientation. 3. Check that the cables are connected and undamaged. 4. Perform the Curing IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required. 5. Replace the cables from the PrintMech PCA to the connection box. 6. Replace the PrintMech PCA. 7. Check there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. 8. Check that all the fans are functioning correctly. Check that the cables of the fans are undamaged and connected. Replace any fans if required: Top Cover Fans. Drying Fans. Curing Fans.