Mã lỗi 16.04:00 — HP DesignJet L28500

Code: 16.04:00

Description: Curing system temperature too low
Causes: The curing system has fallen below the lower temperature limit (below 5°C).
Remedy: 1. Check that the room temperature is within the printer's operating specifications; it should be higher than 15¢XC for printer operation. If it is too low, increase the room temperature. 2. Check whether the Curing IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 3. Check for an obstacle blocking the IR sensor¡¦s view. Ensure that the IR sensor is correctly installed on the printer, with no interference in the infrared light path, and that it is pointing to the substrate. 4. Perform the Curing IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required. 5. Replace the cables from the PrintMech PCA to the connection box. 6. Replace the PrintMech PCA.