Mã lỗi 15.01:00 — HP DesignJet L65500

Code: 15.01:00

Description: Drying system warn-up timed out
Causes: The drying system is unable to warm up in the pre-defined amount of time (to 45°C for standby and normally 55°C or 60°C for printing).
Remedy: 1. Check that the room temperature is within the printer's operating specifications; it should be higher than 15¢XC for printer operation. If it is too low, increase the room temperature. 2. Check that the input voltage is within the printer¡¦s operating specifications: see the Site Preparation Guide. 3. Check whether the substrate loaded on the printer is too transparent or reflective for the IR sensor to detect the surface temperature. You can check this by loading another type of substrate. 4. Check whether the Dryer IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 5. Check that the position of the IR sensor is correct. If it is pointing to a position other than the substrate this will cause an error. 6. Perform the Heating IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required. 7. Replace the cables from the PrintMech PCA to the connection box. 8. Replace the PrintMech PCA.