Mã lỗi 15.05:00 — HP DesignJet LX600

Code: 15.05:00

Description: Problem with the drying system Temperature Sensor
Causes: Signal error detected with the drying system Temperature Sensor.
Remedy: 1. Check that the room temperature is within the printer¡¦s operating specifications. If necessary, remove external sources of heat, such as strong lights, direct sunlight, or heaters. 2. This system error can occur if the ¡¥Minimum Drying Power¡¦ setting in the RIP is too high. Set the Minimum Drying Power to 0, and check whether the error repeats. 3. Check there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. 4. Check that all the fans are functioning correctly. Check that the cables of the fans are undamaged and connected. Replace any fans if required: Top Cover Fans. Drying Fans. Curing Fans. 5. Check whether the Dryer IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 6. Check that the position of the IR sensor is correct. If it is pointing to a position other than the substrate this will cause an error. 7. Perform the Heating IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required. 8. Replace the cables from the PrintMech PCA to the connection box. 9. Replace the PrintMech PCA.