Mã lỗi 16.05:00 — HP DesignJet LX600

Code: 16.05:00

Description: Problem with the curing system Temperature Sensor
Causes: Signal error detected with the curing system Temperature Sensor.
Remedy: 1. Check that the room temperature is within the printer¡¦s operating specifications. If necessary, remove external sources of heat, such as strong lights, direct sunlight, or heaters. 2. Check that the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct orientation. 3. Check whether the Curing IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 4. Check that the cables are connected and undamaged. 5. Perform the Curing IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required. 6. Replace the cables from the PrintMech PCA to the connection box. 7. Replace the PrintMech PCA. 8. Check there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. 9. Check that all the fans are functioning correctly. Check that the cables of the fans are undamaged and connected. Replace any fans if required: Top Cover Fans. Drying Fans. Curing Fans.