Causes: The drying system has fallen below the lower temperature limit (below 15°C).
Remedy: 1. Check that the room temperature is within the printer's operating specifications; it should be higher than 15¢XC for printer operation. If it is too low, increase the room temperature. 2. Check whether the Dryer IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 3. Check that the position of the IR sensor is correct. If it is pointing to a position other than the substrate this will cause an error. 4. Perform the Heating IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required. 5. Replace the cables from the PrintMech PCA to the connection box. 6. Replace the PrintMech PCA.