Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 15.06:00 — HP DesignJet LX800

Code: 15.06:00

Description: Temperature error detected
Causes: There is a mismatch between the temperature detected by the Drying IR Sensor and the amount of electrical power the drying system is receiving.
Remedy: 1. The ink density may be too high, check the User's Guide for the recommended ink density levels. 2. Check that the input voltage is within the printer¡¦s operating specifications: see the Site Preparation Guide. 3. Check whether the substrate loaded on the printer is too transparent or reflective for the IR sensor to detect the surface temperature. You can check this by loading another type of substrate. 4. Check whether the Dryer IR sensor is dirty and requires cleaning. Observe all safety precautions while working in the area of the heaters. 5. Check that the position of the IR sensor is correct. If it is pointing to a position other than the substrate this will cause an error. 6. Perform the Heating IR sensor diagnostic check, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required. 7. Replace the cables from the PrintMech PCA to the connection box. 8. Replace the PrintMech PCA.