Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the ESP is installed in the Carriage. • Check that the ESP is correctly installed and screwed into place. • Check that the ESP cable is not damaged. • Check that the ESP cable is correctly connected to the Carriage PCA. • If the system error persists, replace the ESP Embedded SpectroPhotometer (ESP). • Perform an ESP basic test (CLC), to ensure that the replaced part is working correctly.