Code: 13.AC.EE
Display: 13.AC.EE Door open jam
Description: Door open jam. Lower right cover 2 open; lower right door or HCI inner flap depending on the input accessory configuration.
Remedy: 1. Close the lower right door or HCI inner flap. 2. Depending on input tray configuration, check the tab of the HCI lower right door that engages the door sensor (SW3301). If it is damaged, replace the door assembly. Check the HCI inner flap door (above right HCI tray) to verify that it properly opens and closes. 3. Use the Manual sensor tests menu to toggle the lower right door (Tray 4/5) sensors. If a sensor is not properly functioning, replace the sensor. 4. The HCI (long edge feed guide open) inner flap sensor (PS3306) can not be tested using the Manual sensor tests menu. To test the sensor, open the flap (with product in the ready state) and look for a control panel message to close it. The sensor is part of HCI left paper pickup assembly. 5. Do one of the following: - 500-sheet paper deck: check the connectors (J2005) on the PD controller PCA and the connector (J705) on the PD right door open detection switch. - High capacity input feeder: check the connectors (J3006) on the HCI controller PCA and the connector (J905) on the HCI right door open detection switch.