Code: 50.9X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: W = 9, High fuser temperature 2
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy: 1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. Make sure the product is not located in front of a vent or window where cool air may interfere with the ability of the fuser to heat up. 2. Check the product power source. Make sure the power source meets product requirements. Make sure this is the only device using the circuit. 3. Check the connector (J1) between the fuser and the product. If it is damaged, replace the fuser. 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.