Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred.
Remedy: 59.00.00 or 59.00.10 Feed motor (M102) failure (start-up or rotational) 1. Reconnect the connector (J191) on the feed motor and the connector (J91) on the DC controller PCA. 2. Use the feed motor (M102) drive test in the Component test to verify that the motor is properly functioning. If is not, replace the feed motor (M102). 59.00.30 or 59.00.40 Fuser motor (M299) failure (start-up or rotational) 1. Reconnect the connector (J221) on the feed motor and the connector (J89) on the DC controller PCA. 2. Use the fuser motor (M299) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the fuser motor (M299).