Mã lỗi 66.60.25 — HP LaserJet Enterprise M806

Code: 66.60.25

Display: 66.60.25
Description: Stacker Shutter Motor Error When the shutter clutch (CL101) and stack-ejection lower-roller clutch (CL102) are on, the shutter moves up (closed) when the stack-ejection motor (M102) turns forward and moves down (open, delivery enabled) when the motor turns backwards. This error occurs when the shutter home-position sensor (PI113) indicates no change when the stack-ejection motor (M102) is activated for 3 seconds, indicating the shutter is not moving.
Remedy: 1. Inspect the shutter for damage. If the shutter cannot move freely, replace the shutter assembly. 2. Remove the lower guide (grate-shaped) and check sensor PI113 for damage. 3. Make sure that the sensor is securely fastened to the chassis. 4. Check for proper alignment of the shutter mounted on the back of the grate-shaped lower guide and the left mechanism on the finisher chassis. 5. Make sure that connector J6 and J19 on the stacker controller PCA is fully seated and not damaged. 6. Check CL101 during operation, and make sure that it is functioning correctly by activating prior to the error. Replace CL102 if necessary. 7. If the error persists, replace the stacker controller PCA.