Description: Stacker Assist Motor Error In order to improve stacking performance when ejecting copies, a trailing-edge assist guide is used in addition to the stack-ejection roller to support the rear end of the stack during stack ejection. Error occurs when the stacker trailing-edge guide does not leave its home position (PI109) after the stack trailing-edge motor (M109) has been turned on for 3 seconds.
Remedy: 1. On the product control panel, open the following menus: • Administration • Troubleshooting • Diagnostic Tests • Component Test 2. Test trailing edge motor M109 (stack trailing-edge assist motor) 3. If the trailing-edge assist guide does not move, perform the following steps: 4. Make sure that connector J4 on the stacker controller PCA is fully seated and not damaged also check the wiring at motor M109 and sensor PI109. 5. Replace the operation-tray assembly (processing tray). 6. Only if the error persists and none of the previous steps correct the problem, replace the Stacker