Mã lỗi 6902 — Brother MFC1813

Code: 6902

Display: Self-Diagnostic Will Automatically Restart within 15 minutes.
Description: Rechecking the error after the power switch was turned OFF and then ON again because an error was detected by the fuser unit. (This message is displayed for approximately 15 minutes when the machine is restarted after error code 6901 has occurred.)
Remedy: 1 Connection failure of the fuser unit harnesses Reconnect each harness of the fuser unit. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 4 Main PCB failure Replace the main PCB ASSY. Note: • Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the power switch again and leave the machine for ten minutes. This problem may then be cleared.