Description: Input delay from Tray 5 to HCI SR4 (Tray 5 feed-detect sensor). This is a mispick in Tray 5.
Remedy: Clear the jam. 1. Make sure that the customer is using supported media and that it is loaded correctly. 2. Check Tray 5 pick and separation rollers for contamination and correct mechanical functionality. Replace if necessary. 3. Check for paper or other obstructions to the paper path between Tray 5 and the top of the output of the HCI. 4. Check HCI SR4 (Tray 5 feed-detect sensor) and flag for correct mechanical functionality. Repair or replace if necessary. 5. Check connector J1506 on the HCI controller in Tray 5. 6. Check connector J312 on the dc controller. 7. Replace the dc controller.