Code: 6A00
Display: Drum ! Open the Scanner Cover and Top Cover and slide the green tab across the Drum Unit several times.
Description: Detected discharge that may be attributable to dirty corona wire on the drum unit.
Remedy: • Slide the green tag of the drum unit left and right two or three times to clean the corona wire. • Clean the electrodes of the drum unit. • Replace the drum unit.
1 Dirt on the electrodes of the drum unit Clean the electrodes of the drum unit. 2 Dirt on the high voltage power supply PCB terminal Clean the high voltage power supply PCB terminal. 3 Connection failure of the high voltage PCB flat cable Reconnect the high voltage PCB flat cable. 4 High voltage power supply PCB failure Replace the high voltage power supply PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
1 Dirt on the electrodes of the drum unit Clean the electrodes of the drum unit. 2 Dirt on the high voltage power supply PCB terminal Clean the high voltage power supply PCB terminal. 3 Connection failure of the high voltage PCB flat cable Reconnect the high voltage PCB flat cable. 4 High voltage power supply PCB failure Replace the high voltage power supply PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.