Remedy: action1. Remove and reinstall the fuser. Make sure that it is seated correctly.2. Check the gear for releasing pressure of the fuser. If the gear is damaged, replace the fuser.3. Check the gear for releasing pressure of the fuser on printer side. If the gear is damaged, replace the fuser drive assembly.4. Run the sensor test in the sensor monitor mode to verify that the fuser pressure release sensor is functioning properly. If it is not, replace the fuser pressure release sensor.5. Run the fuser depressurization drive test in the actuator drive mode to verify that the fuser depressurization is functioning properly. If it is not, replace the fuser motor.6. Reconnect the connector (J79) of the fuser pressure release sensor and the connector (J115) on the DC controller PCA.7. Replace the fuser.