Code: 13.B9.Dz
Display: 13.B9.Dz Jam in fuser
Description: Fuser delivery delay jam. This jam occurs when the paper does not reach the fuser output sensor (PS700) in designated amount of time after the Registration sensor (PS103) sensed the leading edge when printing. Z = Tray Printing from. • 13.B9.D1 Fuser delivery delay jam when printing from Tray 1. • 13.B9.D2 Fuser delivery delay jam when printing from Tray 2. • 13.B9.D3 Fuser delivery delay jam when printing from Tray 3. • 13.B9.D4 Fuser delivery delay jam when printing from Tray 4. • 13.B9.D5 Fuser delivery delay jam when printing from Tray 5. • 13.B9.DD Fuser delivery delay jam when printing from Duplexer.
Remedy: 1. Open rear output bin and check for media or obstructions. 2. Remove any jammed paper from the device. Thoroughly inspect the area the jam occurred and clear all paper from the paper path. Paper stopped before fuser: 1. Check the registration area for any blockage, lift registration flap and look for a bit of paper or any blockage. 2. Verify where the leading edge of the paper is when the jam occurs. 3. Verify that the transfer roller is seated properly and not worn or deformed. Replaced it if necessary. 4. If Paper is stopped below toner cartridge in the registration assy, preform manual sensor test on PS103. 5. Make sure the sensor moves freelty and is not damaged. If sensor does not function elevate the issue following your standard support process. 6. Check Media path between transfer and fuser. 7. Check the Paper Feed Assembly for damage or loose belts (see following image) 8. If belt is extremely loose and will not stayed centered when printing, replacing the Paper Feed Assembly. Paper stopped in or at fuser CAUTION: Use caution when handling the fuser. The fuser might be hot when the product is operating. 1. Remove the fuser and inspect the fuser sleeve, pressure roller and delivery roller for blockage and/or damage. Replace fuser as needed. 2. Test fuser delivery sensor (PS700) using the manual sensor test in the Administration, Troubleshooting, Diagnostic Testsmenu to verify that the sensor is functioning properly. If the sensor fails the test, replace the fuser. 3. Run the Fuser motor drive test under the Administration,Troubleshooting, Diagnostic Tests, Component Test menu to verify that the fuser drive and gears are functioning properly. If they are not, replace the fuser drive assembly.