Code: 41.XX.YZ
Display: 41.XX.YZ Error To continue
Description: This section covers all other errors of the form 41.XX.YZ not covered in the previous sections. A product error has occurred. XX = error type Y = fuser mode Z = input tray • XX = 02 Beam detect misprint • XX = 09 Sub thermistor abnormally high • XX = 10 Pickup failure. • XX = 11 Illegal Duplex. • XX = 18 Scan line inclination adjustment • XX = 20 Image drum HV • Y = 0: Photo Media (1, 2, or 3) • Y = 1: Auto Sense (Normal) • Y = 2: Normal (typed not from Auto Sense) • Y = 3: Light media 1, 2, or 3 mode • Y = 4: Heavy media 1 • Y = 5: Heavy media 2 • Y = 6: Heavy media 3 • Y = 7: Glossy media 1 • Y = 8: Glossy media 2 • Y = 9: Glossy media 3 • Y = A: Glossy film • Y = B: OHT • Y = C: Label • Y = D: Envelope 1, 2, or 3 mode • Y = E: Rough • Y = F: Other mode • Z = 0 Envelope feeder • Z = 1 Tray 1 • Z = 2 Tray 2 • Z = 3 Tray 3 • Z = 4 Tray 4 • Z = 5 Tray 5 • Z = 6 Tray 6 • D Duplexer
Remedy: 1. To clear the message, touch the OK button. 2. If the message displays again, turn the product off, and then on again. 3. If the error persists, replace the DC Controller PCA.