Code: 13.A4.D5
Display: 13.A4.D5 Jam in middle right door
Description: This jam occurs when the leading edge of the sheet exits the source tray, but does not reach the Tray 4 feed sensor (SR1PF) in the designated amount of time.
Remedy: 1x500 paper feeder and 1x500 paper deck installed or a 1x500 paper feeder and HCI installed. 1. Open the middle right door, remove any jammed paper, and then close the middle right door. 2. Inspect the Tray 5 pick, feed and separation rollers. Clean or replace them if necessary. 3. Check the connectors at the feed sensor, solenoid, feed motor, and the controller PCA. 4. Use the Tray/bin manual sensor tests to toggle the Tray 5 feed sensor. If the sensor or lever are not properly functioning, replace the Tray 5 paper pickup assembly. 5. Use the Components tests to toggle the Tray 5 solenoid (listen for the solenoid to move). If the solenoid is not properly functioning, replace the Tray 5 paper pickup assembly. 6. Use the Components tests to activate the Tray 5 pickup motor (listen for the motor to rotate). If the motor is not properly functioning, replace the Tray 5 pickup motor. 7. Use the Tray/bin manual sensor tests to toggle the Tray 4 feed sensor. If the sensor or lever are not properly functioning, replace the HCI paper pickup assembly.