Code: 50.7X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: W = 7, Fuser pressure-release mechanism failure
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy: 1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. 2. Check the fuser pressure-release sensor flag. If it is damaged, replace the fuser. 3. Use the fuser pressure-release drive test in the component test to verify that the fuser motor (M3) is properly functioning. If it is not, replace the fuser motor (M3). 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.