Code: 50.4X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: W = 4, Fuser power supply driving circuit error
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy: 1. Remove and then reseat the fuser. 2. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 3. If the error persists, replace the fuser.