Code: 59.05.50
Display: 59.0X.50 Error To continue turn off then on
Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Black image drum start up error (ITB motor; M1)
Black image drum start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.