Code: 59.08.60
Display: 59.0X.60 Error To continue turn off then on
Description: Motor rotational error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Remedy: CMY drum motor (M2) rotation error 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.