Code: 50.7X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: Fuser pressure-release mechanism failure
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
Remedy: 1. Remove and reinstall the fuser. Make sure there is no residual paper in the fuser. 2. Check the connector (J514) between the fuser and the printer. If it is damaged, replace the fuser connector assembly or fuser. 3. Run the sensor test in the sensor monitor mode to verify that the fuser depressurization sensor is functioning correctly. If it is not, replace the fuser. 4. Run the fuser motor test in the actuator drive mode to verify that the fuser motor is functioning correctly. If it is not, replace the fuser motor. 5. If the issue persists, replace the fuser.