Mã lỗi 31.01.03 — HP LaserJet M855xplus Enterprise

Code: 31.01.03

Display: 31.01.03 Document feeder pick error
Description: The document feeder pick (or mis-pick) error occurs when a page cannot be fed from the input tray.
Remedy: 1. Verify that the roller assembly and separation pad are installed correctly. a. Open the top cover of the ADF. b. Push down on the separation pad, and then release it. It should spring back up. If it does not, the spring might be missing. NOTE: The separation pad assembly is mounted to a spring loaded paper access guide, which also moves when pushed down. c. Close the ADF top cover while observing the roller assembly. It will fall against the separation pad, and then pop up when the ADF initializes. 2. Clean the separation pad and rollers. Use a soft, lint-free cloth moistened with water to clean the two rollers and the separation pad. 3. Print a Supplies Status page and verify the remaining life of the Document Feeder Kit. if the remaining life is less than 10%, explain to the customer that the rollers and separation pad are consumables and need to be replaced every 90K pages. 4. Check the stack height in the tray. If the stack height is greater than 7 mm (0.28 in), the originals might get jammed under the feed guides. 5. Verify that the feed guides are not pushed too tightly against the input stack. 6. Check the operation of the registration sensor flag. a. Open the top cover and locate the sensor flag. b. Push down on the flag, and then release it. It should spring back into position. If it does not spring back into position, replace the ADF. c. Close the top cover. 7. Check the input tray. If the clear plastic edge of the input tray is always illuminated with green light, even without paper in the tray, proceed with the following troubleshooting steps. Troubleshooting the internal jam sensors The green LED in the input tray is always on, even when no paper is present. This condition will cause the ADF to continue to pick, even after all the pages have left the input tray. a. Check the ADF ground wire connection at the rear of the scanner. b. If the ground wire is in contact with the CN10 connector test point of the SCB, loosen the screw and move the wire away from the CN10. If the ground wire contacts the CN10 connector test point of the SCB, the formatter will be damaged, resulting in a persistent (will not clear) 31.01.03 document feeder pick error. NOTE: The formatter will have to be replaced. The grounding of the test point results in damage to a component on the formatter, which results in a loss of 3.3v to the SCB.

← Xem tất cả mã lỗi HP LaserJet M855xplus Enterprise

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie