Code: 41.03.YZ
Display: 41.03.YZ Unexpected size in envelope feeder To use another tray, touch "Options "
Description: The product detected a different paper size than expected. Y = Type, Z = Tray • Y = 0 Size mismatch. Detected media is longer or shorter than expected. • Y = A Size mismatch. Detected media too long. • Y = B Size mismatch. Detected media too short. • Y = C Size mismatch. Inter-page gap error. • Z = D Source is the duplexer. • Z = E Source is the envelope feeder. • Z = 2 Source is Tray 2. • Z = 3 Source is Tray 3. • Z = 4 Source is Tray 4. • Z = 5 Source is Tray 5.
Remedy: 1. Make sure that the tray is loaded with the correct paper size and that the sliding paper guides are correctly adjusted. 2. Use the Tray/Bin manual sensor test to verify that the cassette media switch is correctly functioning. 3. If the error persists, replace the lifter assembly.