Code: 50.4X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: Drive circuit fault
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
Remedy: 1. Check the product power source. Make sure that the power source meets product requirements. NOTE: If the power source does not meet the power frequency requirements of 43 to 67Hz, the fuser temperature control does not work correctly and causes this error. 2. If possible, connect the product to an outlet where another product is functioning to verify the power connection. 3. Check and reconnect the connectors (J206 and J219) on the DC controller PCA. 4. If the error persists, replace the cable guide assembly, LVPS, and then the DC controller if necessary.