Code: 50.6X.YZ
Display: 50.WX.YZ Fuser error To continue turn off then on
Description: Open fuser circuit (heating element failure)
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
The fuser has experienced an error. W = fuser error code, X = fuser mode, Y = previous printer sleep state, and Z = next printer sleep state. Fuser modes and sleep states are listed after all 50.WX.YZ troubleshooting.
Fuser Modes
• 0 = Photo Media 1, 2, 3 • 1 = Normal.Auto Sense • 2 = Normal • 3 = Light 1 • 4 = Heavy 1 • 5 = Heavy 2 • 6 = Heavy 3 • 7 = Glossy 1 • 8 = Glossy 2 • 9 = Glossy 3 • A = Glossy Film • B = Transparency • C = Label • D = Envelope 1 • E = Rough
Sleep States
• 0 = Printing • 1 = Standby level 1 (no temperature control) • 2 = Standby level 2 (high temperature control) • 3 = Standby level 3 (middle temperature control) • 4 = Standby level 2 (low temperature control) • 5 = Middle sleep • 6 = Deep sleep • F = Power off
Remedy: 1. Remove and reinstall the fuser. Make sure that it is seated correctly. 2. Check the connector (J514) between the fuser and the printer. If it is damaged, replace the fuser connector assembly or fuser. 3. If the product has been serviced previously, check the connectors (J219 and J206) on the DC controller PCA and the connectors (J90 and J91) on the power line between the low voltage power supply assembly and the fuser. 4. If the issue persists, replace the fuser. 5. If the issue persists, replace the low voltage power supply assembly. 6. If the issue persists, replace the DC controller PCA.