Code: 50.X
Display: 50.X FUSER ERROR
Description: A fuser error has occurred. The values for X are listed below. • 50.1: Low fuser temperature of thermistor (TH1) • 50.2: Fuser warm-up service • 50.3: High fuser temperature of thermistor (TH1) • 50.4: Faulty fuser (drive circuit failure) • 50.8: Lower fuser temperature of thermistor (TH2) • 50.9: High fuser temperature of thermistor (TH2)
Remedy: 1. Power cycle the product to determine if the error is persistent. 2. Verify that the correct fuser model is installed in the product. 3. Verify that the correct voltage fuser is installed in the product. 4. 50.2 errors: Make sure that the connectors J8002 and J1505 are fully seated on the ECU, and connector J18 is fully seated on the fuser. 5. 50.1, 50.3, 50.8, and 50.9 errors: Make sure that the connectors J18 and J1608 are fully seated on the ECU. 6. 50.8 errors: Remove the fuser and make sure that there is no residual media or toner has built up on the fuser. 7. 50.4 errors: Make sure that the power to the product meets the specifications for the product. NOTE: If the power supplied to the product is outside the specifications, the fuser temperature control circuit will not properly work, causing a fuser malfunction. Make sure that the connector J1002 and J1505 are fully seated on the ECU. If the error persists, replace the ECU. 8. If the error persists, replace the fuser.