Code: 50.2
Display: 50.2 Fuser error
Description: Fuser is defective (warm-up failure)
Remedy: 1. Reconnect the connectors of the fuser unit (J802) and DC controller PCA (J104). 2. Measure the resistance between the connector J801-1 and J801-3 on the fusier. If the resistance is not within the range from approximately 220 kOm to 660 kOm (at ambient temperatures), replace the fuser. 3. Reconnect the connectors of the fuser power supply unit (J201, J202, J203). 4. Measure the resistance between the connector J801-1 and J801-2 on the fuser. If the resistance is not within the range from approximately 21 0hm to 25 Ohm (at ambient temperatures), replace the fuser. 5. If the message persists, replace the fuser power supply unit.