Mã lỗi 16.01.01:10, 16.01.02:10 — HP Latex 3000

Code: 16.01.01:10, 16.01.02:10

Description: Curing module X AC power out of range. Module disabled, substrate going under this module won't be cured. But if module is required to print, run subsystem diagnostic. If problem persists, call support.. AC power to the module has been cut.
Causes: a. Safety interlocks or emergency stops have been activated. Usually, if this happens, you will have another system error pointing to the safety element activated. b. ACB is down (then a couple of modules down). c. There has been an AC power cut or AC input tension out of range. d. A resistor has failed. e. A current-sensor PCA has failed.
Remedy: 1. Check that safety elements work properly. 2. Check that all ACBs are OK and in working position. 3. Check whether the customer has power cuts and input voltage problems. 4. Check resistor and replace if necessary. 5. Check PCA and replace if necessary. See Curing and vapor removal PCA.

← Xem tất cả mã lỗi HP Latex 3000