Mã lỗi 48.01.01:01 ... 48.01.04:01 — HP Latex 3000

Code: 48.01.01:01 ... 48.01.04:01

Description: Servo shutdown PPS X not usable, but printing enabled/disabled depending on PPS value. If the problem persists, call your service representative. The meaning of X is: 1 = front right motor 2 = rear right motor 3 = rear left motor (IDS side) 4 = front left motor (IDS side) An error in the closed-loop control (servo control) of the PPS system has occurred. This error indicates that the PPS system is not moving as expected in closed-loop control. The servo-controlled movements consist of applying a specific PWM to a motor (a certain amount of energy) and receiving the feedback of an encoder about the actual movement of the motor after applying that specific PWM. Therefore, if after applying a specific PWM the encoder does not register the expected number of encoder counts (movement), the system will produce this error. Also if the PWM values come out of a certain range of values for the movement (i.e too high PWM to obtain a movement), this error is produced.
Causes: a. PWM signal not supplied to motor. PWM generator (driver) failure, motor failure, cable failure, or disconnected. b. Encoder signals indicating the movement not registered. Encoder disconnected, encoder broken or failed, cable disconnected, or the electrical system receiving the encoder signal has failed. c. PWM is too high due to a mechanical failure. Mechanical system jammed, mechanical system broken or loose. d. PPS system fuse failure. Contact between mechanical system fuse and the motor module.
Remedy: 1. Check the connection of PPS motor power cable and encoder cables. 2. Check that power is supplied to the encoder PCA (LED in the main interconnect). 3. With PPS in the high position, unscrew the X-Y bushing, and check that it can move smoothly through the column. The screwdriver needs to be long. 4. With the PPS in the low position, remove the bottom stopper to the PPS screw (may need to remove the left and right curing module). 5. Remove each PPS screw with a flat screwdriver and then grease the parts. Check that there are no obstructions. 6. If you find plastic or metal obstructions, you will have to remove the corresponding PPS motor assembly later to clean it too. 7. If the high friction error continues, swap the PPS screw from one to the other, and check whether the failure is following the PPS screw. 8. Check mechanical blocking status in the system fuse.

← Xem tất cả mã lỗi HP Latex 3000

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie