Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 48.01.01:02 ... 48.01.04:02 — HP Latex 3000

Code: 48.01.01:02 ... 48.01.04:02

Description: Movement X test fault. Subsystem disabled, but printing may be possible. If not, run diagnostics. If the problem still persists, call HP service. The meaning of X is: 1 = front right PPS movement test fault 2 = rear right PPS movement test fault 3 = rear left PPS movement test fault 4 = front left PPS movement test fault During start-up the printer produces an automatic check by making a small movement forwards and backwards to check the main system functionality (motor moves, encoder signals are received). This error is produced when this test fails. As the movement is very small, this error usually represents a critical error such as cables disconnected, motor failure, or a PCA fault.
Causes: a. Cable connection failure b. Rotor of the motor blocked c. Motor failure/encoder d. Main interconnect board failure (for the right PPS systems) e. Remote controller failure (for the left PPS systems)
Remedy: 1. Check correct connection of PPS motor power cable and encoder cables. 2. Check that the motor is not blocked by anything. 3. Perform the PPS motor diagnostic test. 4. Check mechanical blocking status in the mechanical movement limiter. 5. Replace the PPS motor together with the encoder system and cabling. 6. Replace the main interconnect board or the remote controller board, depending on which part has failed.

← Xem tất cả mã lỗi HP Latex 3000

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie