Mã lỗi 48.02.01:40 ... 48.02.04:40 — HP Latex 3000

Code: 48.02.01:40 ... 48.02.04:40

Description: Servo X current out of range. Run diagnostics. If the problem still persists, call your service representative. The meaning of X is: 1 = front right PPS 2 = rear right PPS 3 = rear left PPS 4 = front left PPS
Causes: a. Environmental conditions of PCA driver b. Overworking conditions of driver in the PCA c. Main interconnect board failure (for the right PPS systems). d. Remote controller failure (for the left PPS systems)
Remedy: 1. Perform carriage beam system recovery. If this is not possible, recover the system manually by removing the motor and aligning the PPS by hand. 2. Perform PPS motor diagnostic test. 3. Check correct connection of PPS motor power cable and encoder cables. 4. Perform move to load position and check the average and maximum points of PWM values for high constant values of friction. If the values are very high, grease the PPS system. If the system error persists, replace the PPS motor mount unit that fails. 5. Replace the main interconnect board or the remote controller board, depending on the failing side. œ E-cabinet PPS control motors: main interconnect œ IDS PPS controlled motors: remote controller board