Mã lỗi 49.03.01:33 — HP Latex 3000

Code: 49.03.01:33

Description: Left or right bar aerosol removal pressure value too low. Run subsystem diagnostic.
Causes: The most probable cause of this error is that the tube that connects the pressure sensor (Sensirion SDP1000- L05) to the aerosol removal box is disconnected or pinched. The sensor is located near the right bar aerosol removal box, and the tube should be connected from the sensor inlet marked as Lo to the inlet at the bottom of the aerosol removal box: œ The tube should not be pinched. œ The tube should go up to the full length of the inlets at the sensor and the box. If the tube is properly connected at both inlets, make sure that it is not pinched by any other element in the carriage. If the pressure sensor reading is too low, the aerosol removal bar will work at full power (the module will be very noisy) and there may be small errors in dot placement that could produce grain.
Remedy: 1. Run subsystem diagnostic. 2. Check that all tubes are properly connected and not pinched. 3. Check cable connections. 4. Replace the sensor.

← Xem tất cả mã lỗi HP Latex 3000