Description: OMAS controller CAN communication error. Substrate advance closed loop lost. Run diagnostic, and call your support representative if the problem persists.. Failure in communication with the OMAS controller board via CAN from the main interconnect board.
Causes: a. OMAS controller power failure b. CAN cable line failure œ From main interconnect board to OMAS controller (cable disconnected or failed) œ From upper engine PCA to main interconnect board c. Vacuum controller PCA CAN line failure d. OMAS controller failure
Remedy: 1. Perform the power diagnostics procedure to supply 24 V power. Check power LEDs on the vacuum controller. If the LEDs are off, check power arrival in the power connector (GND, 5 V and 24 V). 2. If power does not arrive, check cable connections in the main interconnect board and ensure voltages are coming from the main interconnect board connector. 3. If power does not leave the main interconnect board, remove the main interconnect board cover and ensure all power LEDs are on. 4. If all the main interconnect board power LEDs are not on, check power arrival to the main interconnect board, check cable integrity and connectors. 5. If no problem with the cables or connectors is found, replace the main power supply. See E-box PSU. 6. If power arrives to the main interconnect board, replace the main interconnect board. 7. Check data cable connections. 8. Any LAN cable with the necessary length can be used to perform troubleshooting. Replace the cable and restart the printer. If the problem is the LAN cable, HP recommends that you replace it with the appropriate HP service part. 9. Disassemble the OMAS and vacuum PCA box and ensure all connections are correct. 10. Replace the OMAS and vacuum control box.