Mã lỗi 52.01.01:83 ... 52.01.07:83 — HP Latex 3000
Code:
52.01.01:83 ... 52.01.07:83
Description: Drop-detector sensor X not calibrated, sensor disabled. Run subsystem diagnostic. Call your support representative if diagnostic fails, or print quality is affected.. The drop detector is unable to detect its exact position to perform the drop detection. When performing a drop detection, the printer performs a synchronization with the linear encoder and the tail encoder located in the service station motor in order to establish its position with respect to the drop detector windows before performing the actual drop detection action. This error indicates that this synchronization cannot be achieved as the readings from the two encoders do not match according to the movements performed.
Causes: a. Intermittent failure mostly seen when previously used printheads are installed b. Drop detector linear encoder strip not correctly installed or connected c. Drop detector linear encoder sensor dirty, disconnected, or failed d. Incorrect calibration of drop detector system e. Power not arriving to the service station PCA f. Service station interconnect board or cable failure g. Main interconnect board failure
Remedy: 1. Check the functionality of the drop detector. 2. Check the linear encoder strip in the service station. Make sure that the encoder strip is correctly installed in the sensor and well placed in its holders at each end. 3. Check the linear encoder sensor connection. Perform the drop detector diagnostic test to check the linear encoder. If the test fails, replace the encoder system. 4. Perform a drop detector calibration. 5. Ensure power (12 V and 5 V) is reaching the service station interconnect board (power LEDs on). 6. If power is getting through (LEDs on), replace the service station interconnect board and cable. 7. If there is no power (LEDs off), replace the main interconnect board. 8. Check the cable connections of the service station system. If no failure is found, replace the service station interconnect board. 9. Replace the main interconnect board. a. Print the nozzle check by following the directions in the service menu. b. Cancel the drying time to save 10–15 minutes. c. If no failure is detected, there no need to go further, the drop detector is working correctly and the intermittent system error is due to the high usage of the printheads.