Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 30.01.41, 30.01.44, 30.01.45 — HP PageWide Enterprise Color MFP 586

Code: 30.01.41, 30.01.44, 30.01.45

Description: Scanner error The formatter lost connections with the SCB or communication was corrupted. Scanner control board (SCB) communication error.
Remedy: 1. Have the customer turn the printer off, and then on to see if error persists. 2. If issue persists, turn the printer off and remove and then re-seat the formatter then turn the printer back on. 3. If issue persists, Upgrade the firmware. 4. Replace the scanner control board (SCB). IMPORTANT: Add notes for On-Site technician to verify that all cables are connected to the product and to the interconnect board, and scanner control board (SCB) before replacing any parts. 5. Replace the formatter. 6. Verify that all cables are connected to the product and to the interconnect board / formatter and SCB.7. Verify that the scanner control board (SCB) has power.8. Replace the scanner control board (SCB).
Service Technician: 1. Turn the printer off, and then on to see if error persists.2. If issue persists, turn the printer off and remove and then re-seat the formatter then turn the printer back on.3. If issue persists, Upgrade the firmware. 4. Verify that all cables are connected to the product and to the interconnect board / formatter and SCB.5. Verify that the scanner control board (SCB) has power.6. Replace the scanner control board (SCB). 7. Replace the formatter.

← Xem tất cả mã lỗi HP PageWide Enterprise Color MFP 586

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie