Mã lỗi 30.03.XX — HP PageWide Enterprise Color MFP 586
Code:
30.03.XX
Description: XX 30.03.20 : The copy processor board firmware cannot communicate with the PCA on the optical assembly.30.03.22 : Front side illumination calibration failure. The scan module cannot see the illumination module, or marginal illumination. The optical assembly may not be parked under the calibration strip.30.03.23 : Flatbed alignment calibration error.30.03.30 : Flatbed motor shutdown. The scanner control board (SCB) cannot communicate with the flatbed scanner motor.30.03.45 : Scanner control board (SCB) firmware assertion failure. SCB firmware assert controls the scan head motor.
Remedy: 1. Turn the product off, and then on again. As the product turns on, verify that the scan head moves. 2. Check the service event log for other scanner errors, and then resolve those errors. 3. Upgrade the firmware. 4. Verify that the drive belt is in the correct position. 5. Run diagnostics on the flatbed scanner to see if the scan bar moves. 6. Replace the integrated scanning assembly (ISA).