Mã lỗi 02-001 — Samsung CLP770ND

Code: 02-001

Display: S: Low Heat error T: Error: #02-001 Turn off then on
Description: 1. At warm up, the temperature keep up the lower temperature for regular time. 2. In case that the temperature has not reached warm up temperature after warm-up time. 3. At ready, Less than120C and for more than 15 sec. 4. At printing, Less than printing Ref. temp and for more than 15 sec.
Remedy: 1. Turn off the power. And turn on the power. 2. Check the connection of the Fuser unit. And the CN2,5 connector on Main-PBA. 3. Remove the resistance value of the thermostat. If the value is infinity, replace the thermostat. 4. Check the thermistor. If it is defective, replace it. 5. If the problem persists, replace the Fuser unit. 6. Replace the SMPS board or FDB(Fuser drive board).