Display: Motor Failure: #. Turn off then on. Call for service if the problem persists.
Description: Fuser motor operation is abnormal.
Remedy: • A1-1211 : Fuser motor is stopped but machine recognizes it as operational. • A1-1212 : Fuser motor is not operated for print-job. • A1-1213 : Fuser motor is operating but machine recognizes status as "Stopped". 1) Turn the machine off. Check if there are any foreign substances or paper around fuser unit. 2) Check if the fuser unit is damaged. If yes, replace the fuser unit. 3) Remove the rear cover after removing 7 screws. 4) Check if the Fuser motor connectors are connected correctly. 5) If the connection is OK, turn the machine on. Enter SVC mode. Select fuser motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 109-0030) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board(JC44-00150B(220V) / JC44-00149B(110V)). - If the control signal is abnormal, replace the main board(JC92-02516A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.