Mã lỗi A1-2411, A1-2412, A1-2413 — Samsung CLX8640ND

Code: A1-2411, A1-2412, A1-2413

Display: Motor Failure: #. Turn off then on. Call for service if the problem persists
Description: Cyan OPC motor operation is abnormal.
Remedy: • A1-2411 : Cyan OPC motor is stopped but machine recognizes it as operational. • A1-2412 : Cyan OPC motor is not operated for print-job. • A1-2413 : Cyan OPC motor is operating but machine recognizes status as "Stopped". 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the front cover. Check if there are any foreign substances or paper around cyan drum drive unit. 3) Turn the machine on. If the error persists, turn the machine off again. 4) Remove the rear cover after removing 7 screws. 5) Check if the cyan OPC motor connector is connected correctly. 6) If the connection is OK, turn the machine on. Enter SVC mode. Select cyan OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0043) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123C). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board(JC44-00150B(220V) / JC44-00149B(110V)). - If the control signal is abnormal, replace the main board(JC92-02516A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.

← Xem tất cả mã lỗi Samsung CLX8640ND

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie