Display: Motor Failure: #. Turn off then on. Call for service if the problem persists
Description: Yellow toner is not supplied normally.
Remedy: • A1-5211 : Yellow toner supply motor is not operational but toner is supplied. • A1-5212 : Yellow toner supply motor does not operate. • A1-5213 : Yellow toner supply is stopped during operation. 1) Open the front cover. If the yellow toner pipe is blocked, open it. 2) Turn the machine off then on. If the error persists, check the following steps. 3) Enter SVC mode. Select the yellow toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 111-0000 : Toner Dispense Motor Yellow 4) If the motor is not operational, a) Remove the rear cover after removing 7 screws. b) Remove the main board shield. Measure the yellow motor power with DVM. i) If 24V power is generated, replace the yellow toner supply motor(JC31-00159A). ii) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00150B (220V) / JC44-00149B (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02516A).