Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off then on. 2) Turn the machine off. Re-install the fuser unit. Then turn the machine on. 3) If the problem persists, remove the fuser unit. 4) Check if the paper is curled on the fuser belt. 5) If yes, replace the fuser unit. If not, check the followings. a) Remove 8 screws. Remove left/right/top cover. b) Remove 8 screws. Remove the bracket. c) Check if the thermostat(4712-001093) is connected. d) Check if the center and side lamps(4713-001651 : 110V / 4713-001655 : 220V) are in short status. (Measure the resistance value between the common-center and common-side.) e) Check if the thermistor is defective. 6) If the step5 has no problem, replace the fuser unit(JC91-01120A(110V) / JC91-01121A(220V)). 7) If the problem persists, replace these parts in regular sequence. • Fuser Drive Board : JC44-00210A(110V) / JC44-00211A(220V) • Main board : JC92-02516A • SMPS board : JC44-00149B(110V) / JC44-00150B(220V)