Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi A1-4310 — Samsung CLX8650ND

Code: A1-4310

Display: Motor Failure: #. Turn off then on. Call for service if the problem persists
Description: ITB engage motor does not operate normally.
Remedy: 1) Enter SVC mode. Select the T1 engage motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0080) Push the start button and check the motor operation. 2) If the motor is operational, a) Open the side cover. Check if the ITB T1 Coupler pressure lever is pushed normally as shown below. b) If the motor is stopped after 3 times operation, check the following. • Check if the T1 engage DC motor connector is connected correctly. • Check if the photo-sensor(0604-001415) in ITB unit is contaminated or assembled correctly. c) Remove the ITB unit. Check if the ITB T1 Coupler is rotated counterclockwise smoothly. 3) If there is a motor noise or the motor is not operational normally, check the following : a) Remove the rear cover after removing 7 screws. b) Remove the main drive unit. (Refer to 3.3.9. Main Drive Unit) i) Rotate the gear by hand. • If the motor operation is stiff, replace the motor(JC31-00149A) ii) Measure the resistance value with DVM. • If the measured value is out of the standard area (7-10 ohm), replace the motor(JC31-00149A) c) If the motor is normal, measure the motor signal with DVM. • If the phase output voltage is changed in 0-24V(8-10V), the output value is normal. • If the phase output voltage is not changed to 0 or 24V, replace the main board(JC92-02429A).

← Xem tất cả mã lỗi Samsung CLX8650ND

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie