Display: Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists. Actuator Fan Failure #: Turn off then on.
Description: Outer temperature/humidity sensor is defective.
Remedy: • A3-3310 / A3-3311 / A3-3312 : Temperature function is abnormal. • A3-3410 / A3-3411 / A3-3412 : Humidity function is abnormal. 1) Remove the Cover-Left Top[A]. Remove 8 screws. And remove the left cover. 2) Check the temp sensor harness connection. 3) Disconnect the harness. Measure the resistance value of the connector at both ends. If the value is not in 47.5KOm 52.5KOm (at 25C), replace the sensor(JC93-00486A). 4) Remove the rear cover after removing 7 screws. 5) Measure the resistance value of two connectors(CN37_12 / CN37_13) at both ends. 6) If the value is not in 47.5Kom - 52.5KOm (at 25C), replace the harness(JC39-01733A). 7) If the harness and sensor are normal, replace the main board(JC92.02516A)